logo

Détails des produits

Created with Pixso. Maison Created with Pixso. Produits Created with Pixso.
Équipement d'essai pour compteurs stationnaires
Created with Pixso.

Three Phase I-P Close Link Meter Testing Equipment for calibration 6 MTUs

Three Phase I-P Close Link Meter Testing Equipment for calibration 6 MTUs

Nom De Marque: GENY
Numéro De Modèle: YC1893d
Nombre De Pièces: 1 pcs
Prix: Négociable
Conditions De Paiement: L / c, t / t, d / p
Capacité à Fournir: 100 / an
Les informations détaillées
Lieu d'origine:
CHINE
Certification:
ISO, CE
Classe de précision des TIC:
00,05 sur 0.01
Le niveau de tension de sortie de l'essai (neutre en phase):
3x ((24V~288V) ((ou sur mesure)
Gamme de fréquences:
45Hz~65Hz
Alimentation en tension:
3x220/380V ± 10% ((ou personnalisé) 50/60Hz ± 2Hz
Détails d'emballage:
contreplaqué
Capacité d'approvisionnement:
100 / an
Mettre en évidence:

Three Phase meter testing equipment

,

I-P Close Link calibration tool

,

Stationary meter test equipment with warranty

Description de produit

Three Phase I-P Close Link Meter Testing Equipment for calibration 6/12/24/48 MTUs

Guangzhou GENY Electric Co., Ltd. is a professional manufacturer of power metering and testing equipment, established in 2002. With the registered brand "GENY", we are known for reliable quality, innovative design, and strong industry expertise.

We focus on R&D and production of electric meter testing systems, serving utilities and industrial users with trusted solutions.


Specifications



1. Accuracy class : 0.05

2. Easy to calibrate I-P closed links meters with isolated current transformer(ICT)



Technical spec.

YC1893D-ICT-6

YC1893D-ICT-12

YC1893D-ICT-24

YC1893D-ICT-48

Number of meter positions equipped ICT

6

12

24

48

Accuracy class of ICT

0.05 / 0.01

Accuracy

0.05

Power Source

YCS-103-250

YCS-103-600

YCS-103-1200

YCS-103-2500

Standard Meter

SZ03A-K6 / SZ03A-K8 (customized)

Scanning Head

YCG-S Series

Voltage


Test voltage output(Phase-Neutral)

3x(24V~288V)(or customized)

Power of the voltage output

Max. 3x100VA

Max. 3x250VA

Max.

3x500VA

Max.

3x1000VA

Resolution

Better than 0.01% of full scale value of range

Setting accuracy

Better than 0.05% at the final range value

Stability

Better than 0.005% /h (integration time 150s)

Load regulation from 0~max. load

Better than 0.01%

Distortion factor

Better than 0.3% for linear resistance load

Harmonic

2nd~21st  free programmable

Current


Test current output

3x(1mA~100A)

Power of the current output

Max. 3x150VA

Max. 3x350VA

Max. 3x750VA

Max. 3x1500VA

Resolution

Better than 0.01% of full scale value of range

Setting accuracy

Better than 0.05% at the final range value

Stability

Better than 0.005% /h (integration time 150s)

Load regulation from 0~max. load

Better than 0.01%

Distortion factor

Better than 0.3% for linear resistance load

Harmonic

2nd~21st  free programmable

Phase angle


Range

0~360⁰

Resolution

0.01⁰

Setting accuracy

0.1⁰

Frequency


Range

45Hz~65Hz

Resolution

0.01Hz

Error display


Type of error display

Red LED

Resolution of error displays

8 digitals

Other


Voltage supply

3x220/380V±10%(or customized)

50/60Hz ±2Hz

Ambient temperature

-10°C~+40°C

Relative humidity

35%~85%


Three Phase I-P Close Link Meter Testing Equipment for calibration 6 MTUs 0